Functions – ATEIS IDA8 User Manual
Page 406
![background image](https://www.manualsdir.com/files/772583/content/doc406.png)
ATEIS - IDA8
406
© 2012 ATEÏS
Parameter
Range
Comment
Reset
Button
Resets the echo cancellation on the channel
Far-End
Volume
Vu-meter
(dB)
Audio volume of the far-end audio signal.
Near-End
Volume (dB)
Vu-meter
(dB)
Audio volume of the near-end audio signal.
Near-End Level
-90 to 20 (dB)
Volume adjustment of the near-end audio signal
NLP
Selector:
Soft, Medium,
Aggressive, Off
NonLinear Process.
The purpose is to suppress the remaining echo
in a complex environment. It offers four functions:
Off: NLP function off
Soft: weak intensity of remain echo suppression.
Medium: medium intensity of remaining echo suppression.
Aggressive: aggressive intensity of remaining echo
suppression.
NLP Threshold
(dB)
-90 to 20 (dB)
The threshold value of the Nonlinear Process.
Noise
Reduction
Enable
Button
Enable the noise gate
NR Threshold
-90 to 20 (dB)
Threshold of the noise gate
6.1.2
Functions
The AEC component provides four fully independent channels.
On the component, each channel has one input called "far-in", and one output, and one reference called
"far-end". In order to send a proper signal to the other room, the far-end signal will be removed from the
far-in signal,