Major user define fault – ATEIS IDA8 User Manual
Page 124
![background image](https://www.manualsdir.com/files/772583/content/doc124.png)
ATEIS - IDA8
124
© 2012 ATEÏS
Ethernet Broken
If not, the IDA8 will enter in that mode only when the "Bypass Input line" on the rear panel has
broken.
Fault Indication:
LED Indicator:
When this error is detected, the following LEDs will light up:
o
G. Fault LED on the front panel of the IDA8C/S.
Log:
Text messages display at the touch screen of the IDA8C:
"Bypass Mode."
Text messages display at the window [Machine Fault Record] in Ateis Studio:
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.
Fault Handling:
Check the fault list and the "Bypass Input line" on the rear panel.
4.1.7.1.24 Major User Define Fault
Fault Meaning:
The "Fault Define Security" component trigger.
Fault Indication:
LED Indicator:
When this error is detected, the following LEDs will light up:
o
G. Fault LED on the front panel of the IDA8C/S.
Log:
Text messages display at the touch screen of the IDA8C:
"Major User Define Fault"
"Major Fault : xxx" (where xxx = user-defined word.)
Text messages display at the window [Machine Fault Record] in Ateis Studio: