ATEIS IDA8 User Manual
Page 131
![background image](https://www.manualsdir.com/files/772583/content/doc131.png)
Product Features
131
© 2012 ATEÏS
Below fields of the grid:
Leakage Impedance:
The impedance between the Line A/B +/- signal and ground causes the current leakage.
Reference A (ohm):
Shows the impedance value for reference received from Line A output.
Reference B (ohm):
Shows the impedance value for reference received from Line B output.
Reference A&B (ohm):
Shows the impedance value for reference received from Line A & B.
Current Amp:
Shows which amplifier is for the current zone (normal amplifier or backup amplifier).
Measure (ohm):
Shows the impedance value of Line A & B.
Diff(%):
Show the difference percentage of Measure(ohm) and Reference A&B(ohm)
Faults: