Product Features

131

© 2012 ATEÏS

Below fields of the grid:

Leakage Impedance:

The impedance between the Line A/B +/- signal and ground causes the current leakage.

Reference A (ohm):

Shows the impedance value for reference received from Line A output.

Reference B (ohm):

Shows the impedance value for reference received from Line B output.

Reference A&B (ohm):

Shows the impedance value for reference received from Line A & B.

Current Amp:

Shows which amplifier is for the current zone (normal amplifier or backup amplifier).

Measure (ohm):

Shows the impedance value of Line A & B.

Diff(%):

Show the difference percentage of Measure(ohm) and Reference A&B(ohm)