beautypg.com

Ntp server error – ATEIS IDA8 User Manual

Page 126

background image

ATEIS - IDA8

126

© 2012 ATEÏS

o

G. Fault LED on the front panel of the IDA8C/S.

Log:

Text messages display at the touch screen of the IDA8C:

"Modan Offline"

"Modan Port : n offline" (Where n = 1~65535)

Text messages display at the window [Machine Fault Record] in Ateis Studio:

A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.

Fault Handling:

Check the modan client communication.

4.1.7.1.27 NTP Server Error

Fault Meaning:

All the NTP server can't communicate.

Fault Indication:

LED Indicator:

When this error is detected, the following LEDs will light up:

o

G. Fault LED on the front panel of the IDA8C/S.

Log:

Text messages display at the touch screen of the IDA8C:

"NTP Server Error"

Text messages display at the window [Machine Fault Record] in Ateis Studio:

A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.

Fault Handling:

Check the NTP server communication.