Vox@net offline, Vox@net error – ATEIS IDA8 User Manual
Page 114
![background image](https://www.manualsdir.com/files/772583/content/doc114.png)
ATEIS - IDA8
114
© 2012 ATEÏS
A text message displays at the [Machine Fault Record] window in Ateis Studio:
o
Fireman Microphone Button Short:
Text messages display on the touch screen of IDA8C:
"Fireman Error"
"Fireman Button Short"
A text message displays at the [Machine Fault Record] window in Ateis Studio:
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.
Fault Handling:
Check the wire connection of the fireman microphone.
If the wire connection is correct but still indicate a fault, replace the fireman microphone with a
working one.
If the fireman microphone is replaced but still indicate a fault, replace the IDA8C or contact your
technician.
4.1.7.1.13 VOX@NET Offline
Fault Meaning:
The IDA8C/S cannot communicate with VOX@NET server.
Fault Indication:
LED Indicator:
When this error is detected, the following LEDs will light up:
o
G. Fault LED on the front panel of the IDA8C/S.
Log:
Text messages display on the touch screen of IDA8C:
"Voxnet Offline"
A text message displays at the [Machine Fault Record] window in Ateis Studio: