ATEIS IDA8 User Manual
Page 450
ATEIS - IDA8
450
© 2012 ATEÏS
Element Properties:
Name
Initial
Minimum
Maximum
Precision
Unit
Gate On
Off
-
-
-
-
Mute
Off
-
-
-
-
Bypass
Off
-
-
-
-
Thd.
-20.0
-90.0
35.0
0.1
dB
Hold Time
2000
10
5000
10
ms
Release Time
50
10
1000
10
ms
Voice
Recognition
Soft
-
-
-
-
Item list of Voice Recognition:
No.
Name
1
Soft
2
Medium
3
Accurate
Element Description:
Gate On
Lights up when the Gate-Voice is active (open).
Mute:
Mutes the Gate-Voice's module.
Bypass:
Switches off the Gate-Voice's operation.
Thd.:
The threshold to determine and pass the input signal.
Hold Time:
Time to close the output when no more human speech is detected.
Release Time:
Adjusts the fade-out time of the signal to decrease the signal after the hold time.