Control panel – ATEIS IDA8 User Manual
Page 264
![background image](https://www.manualsdir.com/files/772583/content/doc264.png)
ATEIS - IDA8
264
© 2012 ATEÏS
4.2.14.2 Control Panel
Microphone:
The sleek condenser gooseneck microphone. This unidirectional condenser microphone warrants
high quality directive signal pick up from the user and hence less interference from the surroundings.
Monitoring Speaker:
This embedded speaker to play chime when paging or monitor signal from audio processor, it needs
to work with RS485 output component to get audio signal from other DSP components in audio
processor.
Busy LED:
Show the status of zone:
Color
Status
Frequency
Activity
Red
Permanent
Priority of the zone is lower than other sources.
Green
Blinking
°
°
Priority of the zone is higher than other sources.
Green
Permanent
The zone only desired for paging is not using by other
sources.
Fault LED:
To display fault status of system. Following table list the states of fault: