Characteristics – ATEIS IDA8 User Manual
Page 234
![background image](https://www.manualsdir.com/files/772583/content/doc234.png)
ATEIS - IDA8
234
© 2012 ATEÏS
This embedded speaker to play chime when paging or monitor signal from audio processor, it needs
to work with rs485 output component to get audio signal from other DSP components in audio
processor.
7. Fireman Microphone Connector
DIN Connector for fireman microphone connection.
8. All Call Release Button
This button is used to select or deselect all keys.
9. All Call Release Indicator
This indicator lights up if all keys are selected.
10.Event Select Key
These buttons are used to select keys, each key may link to an event for triggering actions like
paging or adjust the value of parameters.
11.Power Indicator
This LED light up when the CD8 is powered on.
12.Evacuation Indicator
Light up when system is under evacuation paging.
Status
Frequency
Activity
Permanent
System is under evacuation paging.
Blinking
°
°
CD-8 does not do a "Plug-in" in Ateis Studio before using.
13.Fault Indicator
To display fault status of system. Following table list the states of fault:
Status
Frequency
Activity
Permanent
There are faults in audio processor.
Blinking
°
°
Lost communication with audio processor.
4.2.9.3
Characteristics
Case
Dimension = 320mm (W) x 190mm (H) x 130mm (D).
Weight = 3.6Kg.
Color = RAL7035.
Power
Item
Voltage
Current Consumption
Comment
DC Input
18V~26V, Typical 24V
120mA
-
Microphone Output
Maximum level = 6dBu.
Output Impedance = 100Ohm.