Rear panel – ATEIS IDA8 User Manual
Page 35
Product Features
35
© 2012 ATEÏS
Line A Error
Line B Error
Backup AMP Error
AMP Line Leakage Error
EVAC Reset Button:
Cancels the event triggered by EVAC button.
Power LED:
This LED lights up when IDA8C is power on.
Network LED:
Show the status of Ateis Net. This LED lights up if more than two deployed IDA8 devices in Ateis
Net.
EVAC Button:
To trigger an event bind with this button.
4.1.1.3
Rear Panel
Speaker Zone Outputs:
There are 8 zones for speaker & amplifier connections. Each zone consists of following connectors
(from left to right):
connector of line A speaker
connector of line B speaker
connector of 100V audio coming from amplifier
The IDA8 output is exactly the same audio signal to line A and B. Two speakers can connect to one
zone for redundancy purposes, one connects to line A, another connects to line B. Both speaker
lines are monitored. That means if damage to a speaker is detected, a global fault "Line A/B Error"
will be generated.
Backup Amplifier I/Os: