Backupamp used state – ATEIS IDA8 User Manual
Page 122
![background image](https://www.manualsdir.com/files/772583/content/doc122.png)
ATEIS - IDA8
122
© 2012 ATEÏS
"Zone n BackUp AMP Rating too low" (where n = 1~8)
Text messages display at the window [Machine Fault Record] in Ateis Studio:
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.
Fault Handling
Check the amplifier power and wiring. Once it's recovered, the LOG will show:
"Zone n Normal AMP OK"
"Zone n Backup AMP OK"
4.1.7.1.21 BackupAmp Used State
Fault Meaning:
A normal amplifier has failed and was replaced by the backup amplifier.
Fault Indication:
LED Indicator:
When this error is detected, the following LEDs will light up:
o
G. Fault LED on the front panel of the IDA8C/S.
Log:
Text messages display at the touch screen of the IDA8C:
"BackupAmp Used State"
"Machine X Zone Y Use Backup Amp Z" (Where X = machine ID, Y = 1~8 and Z = 1~n).
Text messages display at the window [Machine Fault Record] in Ateis Studio:
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.
Fault Handling
Check the normal amplifier power and wiring.