Event – ATEIS IDA8 User Manual
Page 503
Components of Audio Processor
503
© 2012 ATEÏS
Parameters:
Monitor Mode:
There are two options:
o
Voltage: The logic output of component which is triggered by a voltage polarization change.
o
Contact: The logic output of component which is triggered by opening or closing the pin +/- of
the connector in the rear panel.
Response Time:
Determines how quick the system responds to the hardware status changing from Open(Lo) to
Close(Hi) or from Close(Hi) to Open(Lo).
Activation:
Specifies this parameter to determine under what condition the hardware will generate 1 output.
There are two choices:
o
Open(Lo): The component output=1 when the contact open(contact mode) or voltage low
(voltage mode).
o
Close(Hi): The component output=1 when the contact close(contact mode) or voltage hi
(voltage mode).
6.12.4 Event
The components which work with events will be listed in this section.