Element Properties:
Name
Initial
Minimum Maximum Precision
Unit
Trigger On
Off
-
-
-
-
Threshold
-20.0
-50.0
20.0
0.1
dB
Volume
-40.0
-40.0
20.0
0.1
dB
Response Time
0
0
500
10
ms
Hold Time
300
10
5000
10
ms
Element Description:
Trigger On:
Shows if the input signal is activated or not. If the input signal is continuously greater than the
Threshold over the Response Time, the Trigger On value will be set to 1 and the corresponding
logic output is set to High.
Threshold:
The threshold to determine if the audio input is activated or not.
Volume:
The volume of the input signal.
Response Time:
The time to determine if an audio input is activated or not.
Hold Time:
The time to determine if an audio input is activated or not.