background image

Components of Audio Processor

461

© 2012 ATEÏS

can be widened or narrowed. PEQs are capable of making much more precise adjustments to sound
than other equalizers and are commonly used in sound recording and live sound reinforcement.

Control Window:

Element Properties:

Generate Information:

Name

Initial

Minimum Maximum Precision

Unit

Bypass all

Off

-

-

-

-

Bypass

Off

-

-

-

-

Bandwidth

1.00

1.00

4.00

0.01

Octive

Frequency

*1

10

22000

1

Hz

Gain

0

-30.0

15.0

0.1

dB

*1: The initial value of Frequency depends on how many bands of a PEQ. These initial values are
average distribution in range from 10 to 22000 Hz.

Element Description:

Bypass all:

Bypasses the EQ (all the frequency bands).

Bypass:

Bypasses only the selected frequency band.

Bandwidth:

Sets the width around the frequency (Q factor) of selected frequency band.

Frequency: