ATEIS IDA8 User Manual
Page 414
ATEIS - IDA8
414
© 2012 ATEÏS
(Advanced) that is not allowed to mute or bypass the signal of the input. There are two ways to
adjust the delay time for a channel. The first is by adjusting element Delay time, the second is by
adjusting the Element Temp and Distance to compute the delay time. Element Type can be
switched between two modes.
Control Window:
Element Properties:
Name
Initial
Minimum
Maximum
Precision
Unit
Type
On
-
-
-
-
Delay time
0
0
*1
*2
µs
Temp
20
-10
50
0.1
°C
Distance
0
0
*3
0.01
m
*1: The maximum value of Delay time in various type of Delay (Basic).
Type
Maximum
5ms
5000 µs
50ms
50000 µs
100ms
100000 µs
200ms
200000 µs
500ms
500000 µs
1000ms
1000000 µs
2000ms
2000000 µs
*2: The precision value of Delay time in various type of Delay (Basic).
Type
Maximum
5ms
5 µs
50ms
20 µs
100ms
20 µs
200ms
20 µs
500ms
20 µs