Description:
This component controls the input signal's parameters and monitors it. The analog input modules
represent the physical analog inputs which are accessible on the rear panel of the Audio Processor.
There are several separate modules for use with each of the audio board slots. Analog input and
output modules are added automatically to the DSP window of the relevant processor by defining
their module configuration at the time you create them and should not be altered.
Control Window:
Element Properties:
Name
Initial
Minimum Maximum Precision
Unit
Bypass
Off
-
-
-
-
Mute
Off
-
-
-
-
Sensitivity
0dB
-
-
-
-
Phantom Power
Off
-
-
-
-
RTO
Off
-
-
-
-
Overload
Off
-
-
-
-
Volume
-50.0
-50.0
20.0
-
dB
Signal
Off
-
-
-
-
Level
0
-60.0
20.0
0.1
dB