Flash error, I2c error – ATEIS IDA8 User Manual
Page 89
![background image](https://www.manualsdir.com/files/772583/content/doc089.png)
Product Features
89
© 2012 ATEÏS
Name
Description
There is no configuration inside the device.
There is an internal error of the micro controller SPI communication.
There is a data error in the table which stores important information
of the configuration.
There is an internal hardware error of the device.
There is a DSP chip operate error.
Global NT Error
The global ATEIS net card fails. Note: Only for global net IDA8.
The power circuit inside the device has an error.
Last time the machine is unpredictably shut down, please see the
machine log.
The communication between the main controller unit and
telephones fails.
There is an Internal hardware error.
4.1.7.1.1.1 Flash Error
Fault Meaning:
Nand flash inside the IDA8C/S has an error.
Fault Indication:
LED Indicator:
When this error is detected, the following LEDs will light up:
o
System Fault LED on the front panel of the IDA8C/S.
o
G. Fault LED on the front panel of the IDA8C/S.
Log:
Text messages display on the touch screen of the IDA8C as:
"Flash Error"
Also, the text messages display at the [Machine Fault Record] window in Ateis Studio:
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.
Fault Handling:
Contact your technician to repair device.
4.1.7.1.1.2 I2C Error
Fault Meaning:
There is an internal error of I2C communication between micro controllers.
Fault Indication: