Device
Connection Max. Num
Function
PPM AS
PDC
31
Remote console with paging ability.
PSS AS
PDC
1
Remote console for Paging and Event Triggering(Element
Control, Master/Sub Preset Control).
URC AS
PDC
1
Remote console for Master/Sub Preset Controlling and Element
Controlling.
URGP
PDC
1
Evacuation Input extension.
DNM
PDC
31
Auto noise gain for audio signals.
PPM-IT5
Ethernet
1 Active
Over Eth
Paging, Element Control and Master/Sub Preset Control.
URC200
TPC
Ethernet
Eth. Limit
Parameters Control and Master/Sub Preset Control.
CD8
PDC
31
Wall mounted cabinet remote paging console with 8 buttons/
zones.
CD16
PDC
31
Wall mounted cabinet remote paging console with 16 buttons/
zones.
CD Touch
PDC
1
Wall mounted cabinet remote paging console with touch screen
and Fireman Microphone.
PCP
PDC
31
Wall mounted cabinet remote paging console with telephone
styled microphone.
CDPM
PDC
31
Wall mounted cabinet remote paging console with 24 buttons/
zones and 2 extra selectable microphone sources.
PSC
PDC
31
A grouped console is comprised of a pad with a monitoring
speaker, a pad with a gooseneck and 8 buttons/zones, and two
pads with 8 buttons/zones.
Deskpad
PDC
1
A remote dialer for making telephone calls via IDA8's telephone
hardware.
Deskpad
Box
PDC
1
An RF transceiver to communication between Deskpad and
IDA8, use it, Deskpad can work without a physical connection.
Max. Num means you can connect one or more peripheral units through the connector by a using
Junction Box. For example: On the PDC, you can connect 32 PPM AS through junction boxes
and are able to assign IDs in sequence for each unit in Ateis Studio. Note: One IDA8C has 4 PDC
ports, and the sum of remote units is 32. Basically, fireman MIC already has one position
allocated, so this table only shows the maximum as 31.
Eth. Limit: The maximum number of IP that can be assigned over the network.
4.1.2.6
3rd Party Control
The following table lists 3rd Party Control protocols which are IDA8C Supported.
Protocol
Interface
Function
Connection
Settings
Ateis 3rd
Party
Protocol
Ethernet(UDP)
UDP Port =
19761
Read/Write value of parameters.
Stepped adjustment for parameters.
Modbus
PDC(RS485)
PDC Port 1~ 2
Level control
Paging
Read Monitoring Status
Read Evacuation Status
Play Message
Logic I/O Control