Procedure of monitoring setup, Zone monitoring – ATEIS IDA8 User Manual
Page 128
![background image](https://www.manualsdir.com/files/772583/content/doc128.png)
ATEIS - IDA8
128
© 2012 ATEÏS
"Zone n Backup AMP Gain Too Low " (Where n = 1~8)
Text messages display at the window [Machine Fault Record] in Ateis Studio:
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.
Fault Handling:
Check the measured value of the backup amplifier.
4.1.7.2
Procedure of Monitoring Setup
The monitoring setup must be done when the hardware is completely setup. This means the IDA8C/S,
amplifiers, speakers and wiring should be prepared and connected before the monitoring setup, as the
IDA8C/S will get the values from the hardware's initial state for further reference. When the system is
running and reference values are correctly achieved, the IDA8C/S continuously measures the internal
status and compares it with referenced values to determine if there are incorrect processes of zone/
amplifiers.
1. Setup hardware equipment, including an IDA8C/S, a normal amplifier, a backup amplifier, speakers
and wiring between the devices,
2. Make a configuration using Ateis Studio.
3. Store the configuration, then online.
4. Set appropriate settings for your application using Ateis Studio. You can see more details on the
following topic
,
,
.
5. Press the "get reference" button to start the monitoring for the zone you selected.
4.1.7.3
Zone Monitoring
Settings:
First, right click on the IDA8C/S block at the [Devices] window in Ateis Studio: