"Zone n Backup AMP Gain Too Low " (Where n = 1~8)

Text messages display at the window [Machine Fault Record] in Ateis Studio:

A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.

Fault Handling:

Check the measured value of the backup amplifier.

4.1.7.2

Procedure of Monitoring Setup

The monitoring setup must be done when the hardware is completely setup. This means the IDA8C/S,
amplifiers, speakers and wiring should be prepared and connected before the monitoring setup, as the
IDA8C/S will get the values from the hardware's initial state for further reference. When the system is
running and reference values are correctly achieved, the IDA8C/S continuously measures the internal
status and compares it with referenced values to determine if there are incorrect processes of zone/
amplifiers.

1. Setup hardware equipment, including an IDA8C/S, a normal amplifier, a backup amplifier, speakers

and wiring between the devices,

2. Make a configuration using Ateis Studio.

3. Store the configuration, then online.

4. Set appropriate settings for your application using Ateis Studio. You can see more details on the

following topic

Zone Monitoring

,

Normal Amplifier Monitoring

,

Backup Amplifier Monitoring

.

5. Press the "get reference" button to start the monitoring for the zone you selected.