3.2.2 ADC Control Register (ACNT)
Register Description:
ADC Control Register
Register Name:
ACNT
Register Address:
Module 05h, Index 02h
Bits 15 to 11: ADC Input Multiplexer Bits 4 to 0 (ADCMX4 to ADCMX0). These multiplexer bits select the inputs to the ADC and con-
trol the state of the temperature sensor.
MAXQ7665/MAXQ7666 User’s Guide
3-8
Bit #
15
14
13
12
11
10
9
8
Name
ADCMX4 ADCMX3 ADCMX2 ADCMX1 ADCMX0 ADCDIF ADCBIP
—
Reset
0 0 0 0 0 0 0 0
Access
rw rw rw rw rw rw rw r
Bit #
7
6
5
4
3
2
1
0
Name
— ADCDUL — ADCASD
ADCBY
ADCS2
ADCS1
ADCS0
Reset
0 0 0 0 0 0 0 0
Access
r rw r rw rw rw rw rw
r = read, w = write
Note: This register is cleared to 0000h on all forms of reset.
ADCDIF = 1
ADCMX4:ADCMX0
POSITIVE NEGATIVE
MEASURE
00000 AIN0 AIN1 Voltage
00001 AIN1 AIN1
Offset
Voltage
00010 AIN2 AIN3 Voltage
00011 AIN3 AIN3
Offset
Voltage
00100 AIN4 AIN5 Voltage
00101 AIN5 AIN5
Offset
Voltage
00110 AIN6 AIN7 Voltage
00111 AIN7 AIN7
Offset
Voltage
01000 AIN8 AIN9 Voltage
01001 AIN9 AIN9
Offset
Voltage
01010 AIN10 AIN11 Voltage
01011 AIN11 AIN11
Offset
Voltage
01100 AIN12 AIN13 Voltage
01101 AIN13 AIN13
Offset
Voltage
01110 AIN14 AIN15 Voltage
01111 AIN15 AIN15
Offset
Voltage
1x00x Internal Internal
Internal
Temperature
1x01x
AIN0
AIN1
Remote Temperature 1
1x10x
AIN2
AIN3
Remote Temperature 2
11110 — — Reserved
11111 — — Reserved