MAXQ7665/MAXQ7666 User’s Guide
14-25
RL/RLC
Rotate Left Accumulator
Carry Flag (Ex/In)clusive
Description:
Rotates the active accumulator left by a single bit position. The RL instruction circulates the msb of the accumula-
tor (bit 15) back to the lsb (bit 0) while the RLC instruction includes the Carry (C) flag in the circular left shift.
Status Flags:
C (for RLC only), S, Z (for RLC only)
RL Operation:
15 Active Accumulator (Acc) 0
Acc.[15:1]
← Acc.[14:0]; Acc.0 ← Acc.15
Encoding:
15
0
Example(s):
; Acc = A345h, S=1, Z=0
RL
; Acc = 468Bh, S=0, Z=0
RL
; Acc = 8D16h, S=1, Z=0
RLC Operation:
15 Active Accumulator (Acc) 0 Carry Flag
Acc.[15:1]
← Acc.[14:0]; Acc.0 ← C; C ← Acc.15
Encoding:
15
0
Example(s):
; Acc = A345h, C=1, S=1, Z=0
RLC
; Acc = 468Bh, C=1, S=0, Z=0
RLC
; Acc = 8D17h, C=0, S=1, Z=0