Leica Geosystems TPS1100 Professional Series - Reference Manual User Manual
Page 76

76
TPS1100 - Appl. Prog. Ref. Manual 2.2.0en
Reference Line
If the option "Ref. Elev." is set to
"Baseline" you can in addition
calculate the values:
Set to O/S the program will record
both
∆
Offset and
∆
Spatial distance
values.
Set to O/S/P, the program will record
∆
Offset,
∆
Spatial distance and
∆
Perp. Dist of the perpendicular line.
(
Refer to figure in chapter Reference
elevation)
User Disp
Set to YES, the display defined in the
MEAS application will be used.
If set to NO, the "REFERENCE LINE"
default display applies.
Log File
Set to ON, the program will record
measurement data in a log file in the
format described on chapter Log File.
Log FlName
Enter the Log File Name.
Ref. Elev. = Baseline
The reference elevation is the
elevation of the baseline at the
intersection point with the vertical
through current reflector position.
Edit Elev.
Set to YES, point elevations can be
edited directly in "Reference Line
Results" and "L&O Results" dialogs.
∆
Ht is the difference between
entered and measured values and is
updated automatically.
Rec Diff
Set to NONE, no additional
measurement is recorded.
Set to O the program will record
∆
Offset values only.
Set to O/ L, the program will record
both
∆
Offset and
∆
Line values.
Set to O/L/H, the program will record
∆
Offset,
∆
Line and
∆
Height of
target values.
Configuration Editor, continued
Meas. Job
Selection of the measurement job for
recording measurements.
Data Job
Selection of the data job containing
the fix point coordinates (control
data).
Store the current
configuration and proceed
with dialog "1st Point of Baseline".
Press to reset configuration
parameters to their default
values.
Displays date and version of