Leica Geosystems TPS1100 Professional Series - Reference Manual User Manual
Page 19

19
TPS1100 - Appl. Prog. Ref. Manual 2.2.0en
Orientation and Height Transfer
User Disp
YES: The same display mask as the
one used in the system measure-
ment dialog (MEAS) is used for
measurements with "Orientation and
Height Transfer".
NO: The "Orientation and Height
Transfer" default display applies.
Log File
ON, records measurements in a Log-
File. The format is described in
chapter "Log file".
Log FlName
Enter the Log File Name.
Meas. Job
Selection of the measurement job for
recording measurements.
Data Job
Selection of the data job containing
the fix point coordinates (control
data).
Store the current
configuration and proceed to
the dialog "TARGET POINT".
Set the values to default.
Displays date and version.
Exit the program.
Configuration Editor, continued
Ht Acc TP
Height accuracy of the target points.
The entered value, is used as an "a
priori" accuracy in the calculation.
The height is regarded as "error
free", if the computed standard
deviation is within twice the entered
value.
Pos Acc TP
Position accuracy of the target points.
The entered value, is used as an "a
priori" accuracy in the calculation.
The position is regarded as "error
free", if the computed standard
deviation is within twice the entered
value.
Two Faces
YES for dual-face measurement,
NO for single-face.