252
TPS1100 - Appl. Prog. Ref. Manual 2.2.0en
Monitoring
Meas job:
Select the measurement job to
record measured data to.
Control:
The points to be used during the
measurement can be "learned" or
taken from a previously stored data
file by selecting either 'Learned' or a
'*.GSI' file.
Selecting Points
The points and the measurement
method to be used can be selected
in this menu.
Total Pts:
Total number of learned or recorded
points.
Select Pts:
Number of points selected for
measurements.
MeasMethod:
There are 4 measurement methods
to choose from.
<> Measures all repetitions in face I
followed immediately by all
repetitions in face II at each point.
Instrument stays in closest face,
i.e. if last face at point A is face II
then first face at point B is face II.
[A I
A II
B II
B I
C I
…]
[1,2,3 1,2,3
1,2,3
1,2,3
1,2,3
…]
MONIT\ Point Selection
Meas job
: FILE01.GSI a:
Control
:
LEARNED
Totatl Pts :
30
Select Pts :
17
MeasMethod :
<>
Repetition :
3
CONT MEAS SELCT
MC
Selection of points to be
measured.
Set timer requirements.
Start point measurement.
Exit the "Monitoring" program.
Main menu
MONIT\ MONITORING MENU
1 Point Selection
2 Timer Selection
3 Point Measurement
4 End Monitoring
CONT
INFO
MC