Timer selection, Point measurement, Timer selection point measurement – Leica Geosystems TPS1100 Professional Series - Reference Manual User Manual
Page 255: Monitoring timer selection

255
TPS1100 - Appl. Prog. Ref. Manual 2.2.0en
Monitoring
Timer selection
MONIT\ Timer Selection
Beg Date
:
25.10.99
Beg Time
:
08:30:00
End Date
:
25.10.99
End Time
:
17:00:00
Delay
:
0h 45m
CONT
MC
Beg/End Date/Time:
Enter beginning date and time as well
as end date and time. End time must
be later than beginning time and
current time for measurements to
start.
If a point can not be measured, the
TCA or TCRA starts its internal
search routine and, if unsuccessful,
goes on to the next point to be
measured.
Abort the automatic
measurement.
Point measurement
Dialog shows date and time of next
measurement.
MONIT\ Point Measurement
Control
:
LEARNED
Select Pts :
5
Repetition :
3
Meas. Date :
25.10.99
Meas. Time :
8:30:00
MC
Delay:
A delay of up to 99 hours and 59
minutes can be set. Delay is from
beginning to beginning, i.e. if a
complete measurement with all
repetitions takes 30 minutes and
delay is set to 45 min, there will be a
15 min. pause after the end of the
measurements before the instrument
starts to measure again. If Delay is
shorter than measurement time,
instrument measures continuously.
Go back to Main Menu after
completing all settings.