beautypg.com

Chapter 5 specification, 1 common specifications, Normal operating conditions – Yokogawa Standalone MW100 User Manual

Page 214: Transport and storage conditions, Mechanical specifications (excluding ac adapter), Standards compliance, App index

background image

5-1

IM MW100-01E

Specification

1

2

3

4

5

App

Index

5.1 Common Specifications

Normal Operating Conditions

Rated power supply voltage: AC power supply (with or without AC adapter): 100 to 240 VAC

DC power supply: 12 to 28 VDC

Supply voltage range used: AC power supply (with or without AC adapter): 100 to 250

VAC

DC power supply: 10 to 32 VDC

Power supply frequency:

50 Hz ±2%, 60 Hz ±2%

Power consumption:

AC power, or DC power with AC adapter: Approx. 70 VA

max.

DC power supply: Approx. 35 VA max.

* When any six I/O modules are installed

Vibration:

10 to 60 Hz 0.2m/s

2

or less

Shock:

Not allowed

Magnetic field:

400 A/m or less (50/60 Hz)

Position:

Position horizontally with feet down

Structure:

Not explosion-proof

Usage location:

Indoors

Operating altitude:

2,000 m or less

Overvoltage category:

II (per IEC61010-1 CSA22.2 No. 61010-1)

Measurement category:

II (per IEC61010-1 CSA22.2 No. 61010-1)

Pollution degree:

2 (per IEC61010-1 CSA22.2 No. 61010-1)

Transport and Storage Conditions

Environmental conditions during transport and storage:

Ambient storage temperature : –25 to 70°C

Ambient storage humidity:

5% to 95% RH (no condensation)

Vibration:

10 to 60 Hz 4.9m/s

2

or less

Shock:

392 m/s

2

or less (packaged condition)

Mechanical Specifications (Excluding AC Adapter)

External dimensions: Approx. 455 Ч 131 Ч 159 mm (when six slots are attached)

Weight:

Approx. 4.3 kg (maximum total weight)

Installation method: Desktop or floor, panel mount, or attached to a DIN rail

Material:

Steel plate, aluminum die-cast, molded plastic resin

Standards Compliance

CSA:

CSA22.2 No 61010-1, overvoltage category II, measurement

category II, pollution degree 2

UL:

Conforms to UL61010B-1 (CSA NRTL/C)

CE:

EMC directive;

EN61326 Class A

EN61000-3-2

EN61000-3-3

Low voltage directive; EN61010-1; overvoltage category II,

measurement category II,

pollution degree 2

C-Tick:

Conforms with AS/NZS CISPR11 Class A Group1

Overvoltage category II: An index for defining transient overvoltages (includes the

rated impulse withstand voltage, and applies to electrical

equipment supplied with power from fixed installations such as

a distribution board).

Pollution degree 2:

The degree of adherence by a solid, liquid, or vapor that

reduces the withstand voltage or surface resistance factor

(applies only to normal indoor atmospheres (with non-

conductive pollution).

Measurement category II: For measurements performed on circuits directly connected

to the electrical distribution system such as provided by a wall

outlet.

Chapter 5