Thinning operation settings, Thinning operation settings -22 – Yokogawa Standalone MW100 User Manual
Page 144
3-22
IM MW100-01E
Thinning Operation Settings
1.
From the top screen, click
System Setting > Thinning Recording Setting.
Thinning Settings
2.
Select the
Enable check box. Thinning recording is enabled, and you can enter
thinning recording settings.
For a description of the recording start action, see “Saving Data to the CF Card” in section 1.3.
Setting the Thinning Interval, Recording Operation, and Recording Data
Length
3.
Select the thinning time in the
Recording Interval list. A time shorter than the
measurement interval specified for the measurement group cannot be set.
4.
Select a recording stop action in the
Recording Action list.
5.
Select a recording data length from the
Data Length list.
Thinning File Message Settings
6.
Enter the message to be saved to the thinning data file in the Thinning File
Message box.
7.
Click the
Apply button. The setting changes take effect.
3.4 Setting Acquisition Conditions for Measured/Computed Data