3.2 Communication Settings

Connection to the MW100 can be made using Ethernet or serial communications
(optional). Also, when performing communication using the Modbus protocol, Modbus
settings are required. When the login function is enabled, connection is made after
entering a user name and password.

Note

For details on the network such as the IP address and DNS, check with your network
administrator.

If you are performing communications using the Modbus protocol, you must also specify
Modbus settings.

Setting Mode

Ethernet Connection

Setting Up Ethernet for the First Time, IP Address Unclear

Ethernet connections are not possible under the factory default settings. You must enter
an IP address.

1.

After opening an Ethernet connection between the MW100 and PC, run the

MW100 Viewer Software CD-ROM or the MW100 IP address setting software
installed on the PC.

2.

You can select to enter a fixed IP address, or have the address automatically

obtained by DHCP. If you select a fixed IP address, enter the IP address, subnet
mask, default gateway, and DNS.

3.

Skip to the procedures under Connecting to an MW100 with a Specified IP

Address (Including DHCP).

For setting procedures on the MW100 Viewer Software, see the MW100 Viewer Software

User’s Manual

(IM MW180-01E)

You can also power up using a fixed IP address and connect to the network.

When Connecting to an MW100 with a Specified IP Address (Including DHCP).

1.

Open an Ethernet connection between the MW100 and PC, then start the

browser.

2.

Enter the host name or IP address of the MW100 in the browser’s URL/Address

box. The MW100 top page appears. If the login function is set, step 3 is required.

Ex. 1) IP address is 192.168.1.100

http://192.168.1.100/

Ex. 2) Host name is mw100user (requires DNS client settings)

http://mw100user/

3.

Before the top page appears, the

network password entry screen is displayed.

Enter a user name and password and click the OK button.