beautypg.com

5 set ting up t o ols – HEIDENHAIN MANUALplus 4110 User Manual

Page 56

background image

56

3 Machine Mode of Operation

3.5 Set

ting up T

o

ols

In the tool table, enter the tool you want to measure (see “Tool Data”
on page 418
).

Insert the tool and enter the T number in "Set T, S, F."

Activate Measure tool.

Pre-position the tool for the first direction of measurement.

Press the soft key for this direction (e.g. Z direction).

Press Cycle START. The tool moves in the direction of
measurement. When it contacts the touch probe, the
control calculates and saves the set-up dimensions.
The compensation value is deleted.

Pre-position the tool for the second direction of measurement.

Press the soft key for this direction (e.g. X direction).

Press Cycle START. The tool moves in the direction of
measurement. When it contacts the touch probe, the
control calculates and saves the set-up dimensions.
The compensation value is deleted.

Enter the cutting radius.

Transfer the cutting radius to the tool table.

Finding the tool dimensions by using a touch probe