435

8.2 P

a

ra

met

e

rs

Configuration parameters

You can call the Config(uration parameters) [2]
menu item only with "system manager" authorization
(see “Access authorization” on page 453).

The configuration parameters are divided into three
groups:

„

Machine parameters

„

Control parameters

„

PLC parameters (see machine manual)

The parameters are identified with numbers. You can
either call a parameter directly if you already know its
number, or display the parameter list. In the
parameter list, you then simply highlight the desired
parameter and confirm your selection with ENTER.

Some configuration parameters are also
included in the "Current parameters"
menu item.

Machine parameters (MP)

Tool measurement [MP 6]

This parameter defines how to determine the tool set-up
dimensions in setup mode.

„

Type (of tool measurement):

„

0: Touch-off

„

1: Touch probe

„

2: Optical gauge

„

Measuring feed: Feed rate for approaching the touch probe

„

Measuring range:

„

Measuring range: The tool stops when it has traversed to the
maximum measuring range without reaching the touch probe.

Machine dimensions [MP 7]

Within the framework of variable programming, machine
dimensions can be used in NC programs.

„

Dimension 1 in X [mm]

„

Dimension 1 in Z [mm]

„

. . .