2 p a ra met e rs – HEIDENHAIN MANUALplus 4110 User Manual
Page 434

434
8 Organization Mode of Operation
8.2 P
a
ra
met
e
rs
Settings [3]
Set the system to "metric mode" or "inch mode" and define the
behavior for searching the start block.
Changes do not take effect until the control is restarted.
Output to printer—non-functional
Metric/Inch
0: Metric
1: Inch
Start block search
0: Off
1: On (Note: The system must be prepared for the start block
function.)
"PLC parameters [4]" menu item
The PLC parameters are described in your machine manual.
"Graphics parameters [5]" menu item
Standard window size [1]
These parameters define the display area for the graphic simulation
of DIN programs. MANUALplus accounts for the height and width
of the screen and may even enlarge the window size in the vertical
or horizontal direction.
Minimum X coordinate—smallest X coordinate displayed
Minimum Z coordinate—smallest Z coordinate displayed
Delta X—vertical expansion
Delta Z—horizontal expansion
Standard workpiece blank [2]
These parameters define the standard workpiece blank and are
used for calculating the "unrolled lateral surface."
Outside diameter: The "unrolled lateral surface" is calculated from
the diameter.
Length of blank: Horizontal dimension of "unrolled lateral
surface."
Right edge of blank part: Position of the unrolled lateral surface
relative to the coordinate origin. If you enter a positive value, the
"right blank edge" is located to the right of the coordinate origin.
Inside diameter—non-functional
"Machining [6]" menu item
Safety clearances [1]
The following safety clearances are used in several cycles and
during execution of specific DIN cycles (see cycle definitions):
External safety clearance [SAR]
Internal safety clearance [SIR]
External on machined part [SAT]
Internal on machined part [SIT]
Current parameters