beautypg.com

Specifications – dbk48 – Measurement Computing DBK Part 2 User Manual

Page 96

background image

DBK48, pg. 16

967792

8B Isolated Signal Conditioning Module

Specifications – DBK48

Name/Function: DBK48, 16-slot Multi-Purpose Isolated Signal Conditioning Module

Operating Environment:

Temperature: -30°C to 70°C
Relative Humidity: 95% RH, non-condensing

Connectors:

System Connector: DB37 male, mates with P1 connector on primary acquisition device (

Note 1

)

Signal Connector: DB25, 5V output signals from the 8B modules
Power Connectors: Two DIN5 connectors; “Power In” and “Power Out” for daisy-chaining
Input Connections:

8 sets of removable screw terminal blocks, each with 6 connection points as follows:

1

st

channel voltage in (+V in, -V in)

1

st

channel excitation (+E, -E) (

Note 2)

2

nd

channel voltage in (+V in, -V in)

Shunt-Resistor Socket: R0 through R15, plug-in resistor sockets.

One socket per channel for current loop inputs.

Cold-Junction Sensor: Enabled or disabled per channel via jumpers JP0 through JP15.


8B Module Capacity
:

o

Up to 16 voltage input

o

Up to 16 thermocouple

o

Up to 8 modules which require excitation; i.e.

strain gauge, potentiometer, RTD

See latest catalog or contact your sales representative in regard to
the types of 8B Modules available for your application.


Power Requirements
: 10 to 30 VDC; or 120 VAC with AC-to-DC adapter

With 16 thermocouple-type modules (0.03 amps each):

10 VDC @ 0.30 A
15 VDC @ 0.20 A
25 VDC @ 0.12 A

With 8 strain-gage-type modules (0.2 amps each):

10 VDC @ 1.000 A
15 VDC @ 0.667 A
25 VDC @ 0.400 A

Power Consumption: 750 mW from P1, typical

(±15V @ 25mA)

Channel-to-Channel Settling: ±0.05%, typical at 200kHz; ±0.025%, typical at 100kHz

DC Input Fuse: 2 Amp, Mini ATO Fuse, FU-8-2 (Littelfuse #297-002); at board location F3

Isolation

Input Power to System: 250 VDC
Signal Inputs to System: 250 VDC
Input Channel-to-Channel: 250 VDC

Dimensions: 285 mm W × 220 mm D × 45 mm H (11” x 8.5” × 1.75”)

Weight: 1.13 kg (2.5 lb) with no modules installed

Note 1: If attachment to the primary device is through a 100-pin P4 connector, a DBK200 series adapter must be used to

obtain the mating P1 connector.

Note 2: Input devices that require excitation can only be connected to the following channels:

0, 2, 4, 6, 8, 10, 12, 14. The odd-numbered channels do not connect to excitation.

This manual is related to the following products: