background image

DBK208, pg. 4

987594

DBK Option Cards and Modules

1.

Provide raceways (protective wiring routes) for all external I/O wiring.

2.

Keep external I/O wiring away from ribbon cables.

3.

Keep external I/O wiring away from low-voltage signal wiring.

4.

Provide appropriate strain-relief and physical restraint to ensure that the wiring is held securely in the

intended position, and without strain.

5.

Ensure that all wiring with >50V potential is identified by the appropriate color codes and that

warning labels are clearly visible.

6.

Provide physical protection for the I/O interface board. The level of protection is dependent upon the

board’s operating environment.

Partial DBK208

Power

The DBK208 requires an external isolated 5 volt DC supply
with at least 0.25 amp current capacity. External power attaches
to the DBK208 via on-board screw terminal connections. The
board contains capacitors to filter input noise from the power
supply.

Over-current protection is provided by an on-board 0.5 amp
reset fuse in series with the 5 volt supply. Protection from
over-voltage and reverse polarity power conditions is provided
by a 6.8V zener diode.