DBK46, pg. 4

967194

DBK Option Cards and Modules


DBK46 – Specifications

The four analog output channels are updated synchronously relative to scanned inputs, and are clocked

from either an internal clock on the primary acquisition device, such as a DaqBook/2000A; or from a user-

supplied external clock source. Analog outputs can also be updated asynchronously, independent of any

other scanning in the system.
Channels: 4
Resolution: 16 bits
Data Buffer: 256 K sample FIFO
Output Voltage Range: ±10V
Output Current: ±10 mA
Offset Error: ±0.0045V max
Gain Error: ±0.01%
Update Rate: 100 kHz max, 1.5 Hz min (no minimum with external clock)
Settling Time: 10 µsec max to 1 LSB for full-scale step
Digital Feed-thru: a spike of up to 50 mV may occur on the DAC output

each time the DAC output is updated

Clock Sources: 4 programmable clock sources:




The primary acquisition device’s onboard

D/A input clock, independent of the scanning input clock

The primary acquisition device’s onboard

scanning input clock

An external

D/A input clock, independent of an external scanning input clock

An external

scanning input clock


Note
: Specifications are subject to change without notice.