Dbk100 series, In-vehicle thermocouple measurement system – Measurement Computing DBK Part 2 User Manual
Page 189

DBK100 Series
In-Vehicle Thermocouple Measurement System
DBK100/D, DBK100/T, and DBK101
Overview …… 2
System Compatibility:
DaqBook/2000
* Series, DaqScan/2000 Series,
and DaqLab/2000 Series Devices.
*Cannot be used with DaqBook/2000A,
/2000E, or /2000X.
Hardware Setup …… 5
Connecting Thermocouples …… 5
Open Thermocouple Detection …… 7
DBK101 Hub Configuration …… 7
Vehicle Testing and Noise Reduction……9
Power Connections and Analog Common …… 9
Shielding ……10
TC Common Mode …… 10
Software Setup …… 11
Using a Temperature Calibrator …… 14
Specifications …… 15
DBK100/D DBK100/T
DBK101
DBK100/D
is terminated in a Deutsch connector, enabling watertight connections to a mating connector with up to 14
thermocouples. Custom pin-configurations are available to match with existing mating connectors. Inside the Deutsch
connector [tethered to the DBK100/D] is the cold junction sensor, which is measured by the system and used to calculate
the TC reading.
DBK100/T
accepts 14 industry standard mini-TC connectors.
DBK101
You can connect one or two DBK101 hubs to a DaqBook/2000 series A/D module. A total system channel
capacity of 896 channels per DaqBook/2000 system is possible when two DBK100 hubs are used.
Reference Notes:
o
Chapter 2 includes pinouts for P1, P2, P3, and P4. Refer to pinouts applicable to your system,
as needed.
o
In regard to calculating system power requirements, refer to DBK Basics located near
the front of this manual.
DBK Option Cards and Module
907994
DBK100 Series pg. 1