Measurement Computing DBK Part 2 User Manual
Page 194

DBK100/D is terminated in a Deutsch connector, enabling watertight connections to a mating connector
with up to 14 thermocouples. Custom pin-configurations are available to match with existing mating
connectors. Inside the Deutsch connector [tethered to the DBK100/D] is the cold junction sensor, which is
measured by the system and used to calculate the TC reading. The pinout follows.
Female Pin
(Looking at back side of Deutsch)
Male Pin
(Looking at back side of Deutsch)
P1
Signal
P1
Signal
P1
Signal
* f
CH 6 LO
* a
CH 3 HI
* t
CJC+
R
CH 13 LO
B
CH 10 HI
* s
CJC-
* g
CH 6 HI
* k
CH 2 LO
S
CH 13 HI
C
CH 9 LO
* h
CH 5 LO
* m
CH 2 HI
T
CH 12 LO
D
CH 9 HI
* i
CH 5 HI
* n
CH 1 LO
U
CH 12 HI
E
CH 8 LO
* j
CH 4 LO
* p
CH 1 HI
V
CH 11 LO
F
CH 8 HI
* x
CH 4 HI
* q
CH 0 LO
W
CH 11 HI
* b
CH 7 LO
* z
CH 3 LO
* r
CH 0 HI
A
CH 10 LO
* c
CH 7 HI
NOTE!
Do not make connections to
pins t and s! Do not short
pins t and s! Pins t and s are
connected internally to Cold
Junction Compensation!
* Asterisk denoted lowercase letter.
pg. 6, DBK100 Series
907994
DBK Option Cards and Modules