The procedure used to set the [MEASUREMENT] is

explained as follows.

1

Select [OUTPUT] from [OUT1] or [OUT2] on

the program mode screen.

The [OUTPUT] setting screen appears.

The OUT1 settings are performed in this

example.

2

Move the cursor to [MEASUREMENT] by

using the [

] or [] button and press the

[ENTER] button for selecting from the

options.

3

Select the option of [MEASUREMENT] by

using the [

] and [] buttons.

Select one from among A1, A2, A1+A2 and

A1–A2.

4

Press the [ENTER] button.

[MEASUREMENT] is fixed.

When [AREA] is set to [A2] (Area 2), the calculation

with [A1] and [A2] cannot be performed.

Note

OUTPUT Settings

You can specify two types of settings, OUT1 and

OUT2, modifying the measured value for the

respective purposes such as averaging, offset

and calibration. These values can be displayed.

This section describes [MEASUREMENT] from

functions of "Output". Refer to "Output Settings" (page

5-7) for other functions.

Refer to "LIMITS (Tolerance)" (page 5-7).

Refer to "CALIB (Calibration)" (page 5-16) for

calibration.

MEASUREMENT

Selects the area or calculates the value with those of

the areas in OUT1/OUT2.

Four types of measurement can be performed in the

measurement specifications.

A1

Area 1 is measured.

A2

Area 2 is measured.

A1–A2

Measures and calculates the differential
between Area 1 and Area 2.

A1+A2

Measures and calculates the sum of Area 1 and
Area 2.

Functions of the OUTPUT Settings