Default Values and Settings Range (LT-9030 (M))
The default values and the setting range of the setting contents of the displacement mode are shown below.
Displacement Mode
Chapter 3 “Light Intensity Screen” – “Setting the
Light Intensity Level (page 3-8)
Chapter 3 “Measurement Screen” – “Setting the
upper and lower limits of the trend graph display”
(page 3-6)
Chapter 5 "OUT Settings" - "LIMITS" (page 5-7)
Chapter 3 "OUT Settings" - "MEASUREMENT" (page 3-10)
Chapter 3 "OUT Settings" - "SELECT SURFACE"
(page 3-12)
Chapter 5 "OUT Settings" - "AVERAGE " (page 5-8)
Chapter 5 "OUT Settings" - "HOLD MODE"
(page 5-9)
Chapter 5 "OUT Settings" - "OFFSET" (page 5-14)
Chapter 5 "OUT Settings" - "ANALOG output"
(page 5-15)
Chapter 5 "OUT Settings" - "CALIB" (page 5-16)
Chapter 3 "BASIC Settings" - "Scan Width"
(page 3-15)
Chapter 3 "BASIC Settings" - "DARK" (page 3-17)
Chapter 3 "BASIC Settings" - "DARK" (page 3-17)
Chapter 3 "BASIC Settings" - "DARK" (page 3-17)
Chapter 3 "BASIC Settings" - "MASK" (page 3-18)
Chapter 3 "BASIC Settings" - "MASK" (page 3-18)
Chapter 5 "OPTIONAL Settings" - "CAMERA IMAGE" (page 5-18)
Chapter 5 "OPTIONAL Settings" - "FOCUS" (page 5-18)
Chapter 5 "OPTIONAL Settings" - "SCROLL" (page 5-18)
Chapter 5 "OPTIONAL Settings" - "GRAPH DISPLAY" (page 5-18)
Chapter 5 "OPTIONAL Settings" - "DIGITS"
(page 5-18)
Chapter 5 "OPTIONAL Settings" - "I/O" (page 5-20)
Chapter 5 "OPTIONAL Settings" - "GAIN" (page 5-20)
Setting contents
Reference pages
Setting range
Default
value
30
+100.00
–100.00
+100.00
–100.00
+600.00
–600.00
+200.00
–200.00
+100.00
+100.00
+400
–400
Displacement
Maximum
[MAX]
Maximum
[MAX]
2
0.00
0.00
0.00
120/4
100
20
OFF
OFF
ON
ON
OFF
Normal
[NORMAL]
Binary
[BINARY]
Standard
Center fix
Medium
Displacement mode
Program
Run
Programs
GRAPH DISPLAY
OUT settings
(OUT1/OUT2)
Basic
settings
Optional
settings
Tolerance
Output
Calibration
Scan
Dark
Mask
Display
I/O
GAIN
1st point/measured value
1st point/calibrated value
2nd point/measured value
2nd point/calibrated value
Analog +10V
Analog –10V
Measurement mode
Offset
Scan Width
Darkout
Darkout range (HI)
Darkout range (LO)
Mask
Mask range (HI)
Mask range (LO)
Camera Image
Focus
Graph display
Scroll
DIGITS
GAIN
I/O
Light intensity level
OUT1 Upper limit
OUT1 Lower limit
OUT2 Upper limit
OUT2 Lower limit
Upper limit
Lower limit
Select
mesurement
Measurement surface
(One surface)
Measurement surface
(Two surfaces)
Number of measurement
times for averaging
OFF, ON
OFF, 120/2, 120/4,
120/8, 240/2, 240/4,
240/8, 400/2, 400/4,
400/8, 560/2, 560/4,
560/8, 4/1
OFF, ON
ON, OFF
ON, OFF
0~255
–9999.99 ~ +9999.99*
–9999.99 ~ +9999.99*
–9999.99 ~ +9999.99*
–9999.99 ~ +9999.99*
–9999.99 ~ +9999.99*
–1500 ~ +1500
1 ~ 255
0 ~ 254
OFF, 1-Digit, 2-Digit
Binary, Judgment output
Low, Medium, High
Displacement, Transparent object thickness
MAX, M1, M2, +1P, +2P, +3P
+4P, –1P, –2P, –3P, –4P
2 ~ 128 (256 ~ 4096)
Center fix, Maximum displacement,
Minimum displacement,
Average displacement
Normal [NORMAL], Auto peak hold [A.PEAK H],
Auto bottom hold [A BOTM H], Auto P-P hold
[A P-P H], Average hold [AVER. H],Peak hold
[PEAK HLD], Bottom hold [BOTTOM H], P-P
hold [P-P HOLD], Sample hold [SAMPLE H]
Normal, High sensitivity
Chapter 5 "OPTIONAL Settings" - "DISPLAY UNIT"
(page 5-19)
Display unit
μm
μm,mil
*The values differ according to the setting of the digit and the area.