Timing chart, Normal measurement (when profile output is off) – KEYENCE LT-9001 Series User Manual

Page 123

background image

7

Chapter

I/O

Terminal

E LT-9001-IM

7-9

Timing Chart

The timing charts in the normal measurement and in the profile data output are as follows.

Normal/Auto peak hold/Auto bottom hold/Auto peak-to-peak hold

The minimum input time (T1), sampling cycle (T2), scanning change time (T3), RESET time (T4), and

update cycle (T5) vary according to the settings.

Refer to "Timing Details" (page 7-13) for details.

T3 is required only when the scanning setting is to be changed.

Stability output is always output in a sampling cycle (T2).

Peak hold/Bottom hold/peak-to-peak hold/average hold/sample hold

The minimum input time (T1), sampling cycle (T2), scanning change time (T3), and RESET time(T4) vary

according to the settings.

Refer to "Timing Details" (page 7-13) for details.

With RESET input, the internal measured value is fixed after the RESET time has elapsed.

T3 is required only when the scanning setting is to be changed.

STABILITY output is always output in a sampling cycle (T2).

Normal Measurement (When Profile Output is OFF)

MinT1