Status table, Specifications – KEYENCE LT-9001 Series User Manual
Page 152

9-4
Specifications
■ Common to the displacement mode and the shape mode
Status Table
E LT-9001-IM
Specifications
9
Chapter
Screen
Input
Output
RS-232C
Measured
Limits
Timing/Reset Auto-zero
Program No.
Judgment
Stability
Incoming
Response
value display
display
change
output
output
Numerical
Measured
Judgment
Comparator
value
value display
result
Over range at Display range
HI
HI
plus side
upper limit
Over range at Display range
LO
LO
minus side
lower limit
Dark
--DARK--
Not available
All OFF
Judgment
--------
Not available
All OFF
standby
During RESET
--------
Not available
All OFF
processing
During setting Not available Not available
Same as during
Returns
measurement
an error
Input error
Error display Judgment
Same as during
OK
measurement
Other errors
Error display Not available
All OFF
OFF
Returns
an error
When power
Title screen
All OFF
OFF
Returns
is turned on
an error
* OK/NG indicates a validity/invalidity of input.
During
measurement
Normally
active
depending
on the
measurement
status
Pages
7-5 and
7-9
OK
OK
NG
NG
NG
OK
NG
NG
OK
OK
■ When the profile output in the displacement mode and the profile mode is set to OFF
Output
Analog output
Binary output
Data output
Strobe output
Numerical value
Over range at plus side
+10.5V
+1048575
(0x0FFFFF
)
Over range at minus side
-10.5V
-1048576
(0x100000)
Dark
-10.5V
-1048576
(0x100000)
Judgment standby
-10.5V
-1048576
(0x100000)
During RESET processing
-10.5V
-1048576
(0x100000)
During setting
Same as during measurement
Input error
Same as during measurement
Other errors
-10.5V
0 (0x000000)
OFF
When power is turned on
-10.5V
0 (0x000000)
OFF
Output according to the
measured value of
OUT1/OUT2
OUT STB
* Only when I/O is
binary.
pages 7-10 and 7-13
Voltage according to the
measured value of
OUT1/OUT2
When it exceeds ±10 V,
+10.5 V at the plus side
-10.5 V at the minus side
During
measurement
OK
OK