Default Values and Settings Range

The default values and the settings range of the profile mode are shown below.

Profile Mode

E LT-9001-IM

Basic

Operations

2

Chapter

Chapter 5 "OPTIONAL Settings" - "DISPLAY UNIT"
(page 5-19)

Display unit

μm

μm,mil

Normal, High sensitivity

Profile mode

Program

Run

Programs

GRAPH DISPLAY

Area ranges

OUT settings
(OUT1/OUT2)

Tolerance

Output

Calibration

Basic

settings

Optional

settings

Scan

Dark

Display

I/O

GAIN

Area

Smooth

Profile

output

Setting contents

Reference pages

Setting range

Default

value

30

+300.00

–300.00

+200.00

–200.00

–400

–300

+300

+400

+200.00

–200.00

2

0.00

Normal

[NORMAL]

A1(OUT1)
A2(OUT2)

+100.00

+100.00

0.00

1100/5

0.00

AVE

AVE

OFF

OFF

OFF

OFF

OFF

ON

ON

0

2

2

Binary

[BINARY]

Standard

Center fix

Chapter 5 "OUT Settings" - "CALIB" (page 5-16)

Chapter 4 “Measurement Screen” – “Display of
Profile Waveform” (page 4-6)

Chapter 4 “Light Intensity Screen” – “Changing
the Ranges of the Areas” (page 4-9)

Chapter 5 "OUT Settings" - "LIMITS" (page 5-7)

Chapter 4 "OUT Settings" - "Measurement"
(page 4-12)

Chapter 4 "BASIC Settings" - "AREA" (page 4-13)

Chapter 5 "OUT Settings" - "AVERAGE " (page 5-8)

Chapter 5 "OUT Settings" - "HOLD MODE"
(page 5-9)

Chapter 5 "OUT Settings" - "OFFSET" (page 5-14)

Chapter 5 "OUT Settings" - "ANALOG output"
(page 5-15)

Chapter 4 "BASIC Settings" - "SCAN WIDTH"
(page 4-14)

Chapter 4 "BASIC Settings" - "SCAN center" (page 4-15)

Chapter 4 "BASIC Settings" - "FINE mode" (page 4-15)

Chapter 4 "BASIC Settings" - "DARK" (page 4-16)

Chapter 4 "BASIC Settings" - "SMOOTH" (page 4-17)

Chapter 4 "OPTIONAL Settings" - "AUTO SLANT COR" (page 4-18)

Chapter 4 "OPTIONAL Settings" - "PROF OUT" (page 4-19)

Chapter 5 "OPTIONAL Settings" - "CAMERA IMAGE" (page 5-18)

Chapter 5 "OPTIONAL Settings" - "FOCUS" (page 5-18)

Chapter 4 “Light Insity Screen” – “Setting the Light
Intensity Level” (page 4-8)

Chapter 5 "OPTIONAL Settings" - "GRAPH DISPLAY" (page 5-18)

Chapter 5 "OPTIONAL Settings" - "DIGITS" (page 5-18)

Chapter 5 "OPTIONAL Settings" - "I/O" (page 5-20)

Chapter 5 "OPTIONAL Settings" - "GAIN" (page 5-20)

Normal [NORMAL], Auto peak hold [A.PEAK H],
Auto bottom hold [A BOTM H], Auto P-P hold
[A P-P H], Average hold [AVER. H],Peak hold
[PEAK HLD], Bottom hold [BOTTOM H], P-P
hold [P-P HOLD], Sample hold [SAMPLE H]

120/2, 120/5, 120/10,
250/2, 250/5, 250/10,
500/2, 500/5, 500/10,
1100/2, 1100/5,
1100/10

0~255

–9999.99 ~ +9999.99*

–9999.99 ~ +9999.99*

–9999.99 ~ +9999.99*

–9999.99 ~ +9999.99*

–550 ~ +550

–9999.99 ~ +9999.99*

2 ~ 128

AVE, MAX, MIN, DIFF

AVE, MAX, MIN, DIFF, AREA

–550 to +550

ON, OFF

ON, OFF

OFF, ON

OFF, 25%, 50%, 75%, 100%

ON, OFF

ON, OFF

OFF, 1-Digit, 2-Digit

Binary, Judgment output

Center fix, Maximum displacement,
Minimum displacement,
Average displacement

A1, A2, A1–A2, A1+A2

2, 4, 16

Light intensity level

Upper limit

Lower limit

Upper limit

Lower limit

Area1, range1

Area1, range2

Area2, range1

Area1, range2

Select

measurement

Number of measurement

times for averaging

Analog +10V

Analog –10V

Measurement mode

Offset

1st point/measured value

1st point/calibrated value

2nd point/measured value

2nd point/calibrated value

SCAN center

SCAN WIDTH

Camera Image

Focus

Graph display

Minimum number of

non-displayed digits

GAIN

I/O

AUTO SLANT COR

FINE Mode

Darkout

Averaging

Smoothing

Profile output

Area1

Area2

CORRECT

* The values differ according to the setting of the digit and the area.