7

Chapter

I/O

Terminal

7-15

E LT-9001-IM

Scanning change time (T3)

The scanning change time (T3), which is a duration to change the scanning settings such as scan

width/interval, measurement center, or FINE mode, is as follows.

The scanning change time (T3) = Sampling cycle before the change (T2) + (Sampling cycle after the change

(T2)

÷ 2) + 170 [ms]

Profile output time (When Profile output is ON) (T6)

Minimum input time

Refer to "Timing Chart" (page 7-9) for the response delay time to the input.

• The minimum input time (T1) varies according to the settings.

Refer to "Minimum Input Time (T1)" (page 7-13) for details.

Timing chart for LASER REMOTE input

* T2 is a sampling cycle. (

Page 7-13)

Timing Details (Common to the LT-9001 Series)

Input

Specification

TIMING/ZERO/RESET

ON

: T1

P1 to P3

OFF : T1

[ms]

Profile output time (T6)

Scanning

width/interval

Data (N)

FINE=OFF

FINE=ON

120/2

61

39.1

157

120/5

25

16

80

120/10

13

8.32

41.6

250/2

126

80.7

323

250/5

51

32.7

164

250/10

26

16.7

83.2

500/2

251

160.7

643

500/5

101

64.7

324

500/10

51

32.7

164

1100/2

551

353

1411

1100/5

221

142

708

1100/10

111

71.1

356

* Some errors may occur in the profile output time (T6) due to individual differences of the measuring unit.

emmission

Emmission

Measurement

Measurement

Hold

Max T2

×

2

4ms

25ms