Video output, Functions of the i/o signals, Functions of the i/o signals video output – KEYENCE LT-9001 Series User Manual
Page 119

7
Chapter
I/O
Terminal
E LT-9001-IM
7-5
Connects the external monitor for display and operation.
Matching connector: PIN connector (plug)
This section describes the functions of the I/O signals.
Refer to pages 7-2 and 7-3 for the layout of each terminal.
Stability output
Judgment output
I/O for measurement control
Functions of the I/O Signals
VIDEO Output
Name
Description
Reference page
STABILITY
Outputs when conditions are satisfied
Page 7-4
(NPN open collector output is ON).
Displacement mode:
When both OUT1 and OUT2 satisfy the following
conditions
• DISTANCE and THICK
When a measured value is obtained exceeding
the specified light intensity level
• SLANT and
ΔSLANT
When multiple numbers of data obtain a
measured value exceeding the specified light
intensity level
Profile mode:
When both AREA1 and AREA2 satisfy the following
conditions
• Other than AREA (amount of space)
When a measured value is obtained with
more than one data point within the area
exceeding the specified light intensity level.
• AREA (amount of space)
When measured value of area is obtained with the
multiple numbers of data within area exceeding
the specified light intensity level.
Name
Description
Reference page
3-step Judgment
Outputs according to the limit results,
Page 7-4
output (HI, GO, LO) (N.O.).
OUT1 and OUT2 can be output independently.
Name
Description
Reference page
TIMING input
Performs an external synchronization input of
Page 7-3
the measurement mode.
RESET input
Resets the measured value.
Page 7-3
* Common inputs for OUT1 and OUT2