beautypg.com

Video output, Functions of the i/o signals, Functions of the i/o signals video output – KEYENCE LT-9001 Series User Manual

Page 119

background image

7

Chapter

I/O

Terminal

E LT-9001-IM

7-5

Connects the external monitor for display and operation.

Matching connector: PIN connector (plug)

This section describes the functions of the I/O signals.

Refer to pages 7-2 and 7-3 for the layout of each terminal.

Stability output

Judgment output

I/O for measurement control

Functions of the I/O Signals

VIDEO Output

Name

Description

Reference page

STABILITY

Outputs when conditions are satisfied

Page 7-4

(NPN open collector output is ON).

Displacement mode:

When both OUT1 and OUT2 satisfy the following
conditions
• DISTANCE and THICK

When a measured value is obtained exceeding
the specified light intensity level

• SLANT and

ΔSLANT

When multiple numbers of data obtain a
measured value exceeding the specified light
intensity level

Profile mode:

When both AREA1 and AREA2 satisfy the following
conditions
• Other than AREA (amount of space)

When a measured value is obtained with
more than one data point within the area
exceeding the specified light intensity level.

• AREA (amount of space)

When measured value of area is obtained with the
multiple numbers of data within area exceeding
the specified light intensity level.

Name

Description

Reference page

3-step Judgment

Outputs according to the limit results,

Page 7-4

output (HI, GO, LO) (N.O.).

OUT1 and OUT2 can be output independently.

Name

Description

Reference page

TIMING input

Performs an external synchronization input of

Page 7-3

the measurement mode.

RESET input

Resets the measured value.

Page 7-3

* Common inputs for OUT1 and OUT2