KEYENCE LT-9001 Series User Manual

Page 62

background image

Operations

and

Fun

ction

Settings

in
the

Displacement

Mo

de

3

Chapter

E LT-9001-IM

3-16

Basic Settings

Scan center (Supported only in the LT-9010 (M))

Set the scan center for scanning.

Refer to "Default Values and Setting Range"

(page 2-25) for the setting range and limitations.

The procedure used to set the scan center is

explained as follows.

1

Select [SCAN] from [BASIC] on the program

mode screen.

The scan setting screen appears.

2

Select [SCAN CENTER] and press the

[ENTER] button.

The measurement screen appears and the

center position is indicated by the vertical cursor

displayed in yellow.

3

Move the vertical cursor (yellow) by using the

[t] and [s] buttons and set the scan center.

4

Press the [ENTER] button.

The scan center is fixed.

If the [ZERO] button is pressed while setting the scan

center, the parameter is set to "0".

Reference

The procedure used to set the scan width/interval is

explained as follows.

1

Select [SCAN] from [BASIC] on the program

mode screen.

The scan setting screen appears.

2

Select [SCAN WIDTH].

3

Select the scanning width and pitch by using

the [

] and [] buttons.

4

Press the [ENTER] button.

The scan width/interval is fixed.

When the scan width is wide and the pitch is narrow,

the bigger the differential between the two settings

becomes, the more time that is needed for

measuring. Determine the required stability and set

the scanning width and pitch accordingly.

The displacement mode calculates the data of

multiple points obtained from a single scan and

calculates the displacement data.

Use the profile mode to measure the shape.

Refer to "Operations and Function Settings in the

Profile Mode" (page 4-1).

Reference