5-20

OPTIONAL Settings

The LT-9001 Series has two types of gains to receive

the light intensity. You can choose one from the

following two options.

• STANDARD

: Measures the target

with the standard

gain.

• HI GAIN (High sensitivity)

: Measures the target

with higher gain.

It is recommended to measure the target with the

[STANDARD] gain if there is no problem with the

measurement. With [HI GAIN], the gain of the noise

element is also increased and that may cause the

unstable measurement.

If the light intensity is saturated, the measurement

become unstable.

The procedure used to set the sensitivity setting is as

follows.

1

Select [GAIN] from [OPTIONAL] on the

program mode screen.

The screen appears for setting the sensitivity.

2

Select [GAIN].

3

Select [STANDARD] or [HI GAIN] by using the

[

] and [] buttons.

4

Press the [ENTER] button.

The sensitivity setting is fixed.

Note

GAIN (Sensitivity)

Performs settings for the control I/O on the back

of the controller.

The LT-9001 Series has two types of I/O setting as

follows.

"Control I/O" (page 7-3)

The procedure used to set the I/O is explained as

follows.

1

Select [I/O] from [OPTIONAL] on the program

mode screen.

The screen appears for setting up the I/O.

2

Select [I/O].

3

Select [BINARY] or [JUDGMENT] by using the

[

] and [] buttons.

4

Press the [ENTER] button.

The I/O setting is fixed.

BINARY

Outputs the measured value in 21-bit binary
number.

"Binary output" (page 7-7)

JUDGMENT

Outputs the determination whether or not the
measured value is within the tolerance.

"LIMITS (Tolerance)" (page 5-7)

I/O