Outrigger control valves – Lull 6K Service Manual User Manual
Page 632

Outriggers
10-14
Service Manual — Models 644B, 6K, 844C, 8K, 1044C, 10K
1. Loosen, but do not remove the two (2) jam nuts on the proximity switch
body.
2. Check the gap between switch and boom. The gap must be within the
range specified in Fig. 10-9.
3. If the boom extension proximity light does not illuminate when the
boom is extended to the specified distance (approximately 21 feet with
a tilting tower or 25 feet with a standard carriage), adjust the proximity
switch to slightly reduce the gap. Do not exceed gap tolerances
specified in Fig. 10-9. Snug jam nuts to hold switch in position.
4. Extend the boom and check operation of the boom extension proximity
light. The light must come on when the boom is extended to specified
distance (approximately 21 feet with tilting tower or 25 feet with
standard carriage). If the light does not illuminate, stop and retract the
boom. Repeat Step 3.
5. Tighten the jam nuts.
Outrigger Control Valves
Description
Fig. 10-10: Outrigger Controls
(Ref. Fig. 10-9) The remote controls are located to the right of the seat and
consists of three sections. One section is used for frame tilt control (rear
control) and two are outrigger controls. The pressure range for each
section is 116–410 psi. The front control raises and lowers the right
outrigger and the middle control raises and lowers the left outrigger.
V
1087
Left
Outrigger
Frame
Tilt Control
Right
Outrigger