HP StorageWorks 2.32 Edge Switch User Manual
Page 218
Information and error messages
218
Switch clock alert
mode must be cleared
before enabling period
synchronization.
Clock alert mode is enabled
through the Configure FICON
Management Server dialog box
and user is attempting to enable
Periodic Date/Time
Synchronization through the
Configure Date and Time dialog
box.
Disable clock alert mode through the
Configure FICON Management
Server dialog box.
The add firmware
process has been
aborted.
You aborted the process to add a
firmware version to the HAFM
appliance’s firmware library.
Verify the firmware addition is to be
aborted, then click OK to continue.
The data collection
process failed.
An error occurred while
performing the data collection
procedure.
Try the data collection procedure
again. If the problem persists, contact
the next level of support.
The data collection
process has been
aborted.
You aborted the data collection
procedure.
Verify the data collection procedure is
to be aborted, then click OK to
continue.
The default zone must
be disabled to
configure.
You attempted to change the
management style to Open Fabric
and the default zone is enabled.
Disable the default zone and repeat
the operation.
The Ethernet link
dropped.
The Ethernet connection between
the HAFM appliance and the
director is down or unavailable.
Establish and verify the network
connection.
The firmware file is
corrupted.
A firmware version file is corrupt.
Contact the next level of support to
report the problem.
The firmware version
already exists.
This firmware version already
exists in HAFM appliance’s
firmware library.
Informational message only—no
action is required.
The following
parameters cannot be
disabled while
Enterprise Fabric Mode
is active: Insistent
Domain ID, Rerouting
Delay, Domain RSCNs.
You attempted to disable these
parameters in the Configure
Switch Parameters dialog box
while Enterprise Fabric Mode is
enabled.
Disable Enterprise Fabric Mode
through the Enterprise Fabric Mode
dialog box in HAFM, then disable the
parameters.
The link to the
director is not
available.
The Ethernet connection between
the HAFM appliance and the
director is down or unavailable.
Establish and verify the network
connection.
Table 10
Element Manager messages (continued)
Message
Description
Action