Edge Switch Element Manager user guide 129

6.

Enter a percentage from 1 through 100 for % utilization. When throughput reaches this

percentage of port capacity, a threshold alert will occur.

7.

Enter the amount of cumulative minutes in which the % utilization can exist during the

notification interval before an alert is generated. You can also click At any time if you want an

alert to occur whenever the set % utilization is reached. The valid range is 1 to the interval

set.

8.

Enter the interval in minutes in which throughput is measured and threshold notifications can

occur. The valid range is 5 minutes to 70,560 minutes (1,440 minutes equals 24 hours.).

9.

Click Next. A new screen for choosing ports for the alerts is displayed, as shown in

Figure 54

.

Figure 54

New Threshold Alerts dialog box - third screen (Edge Switch 2/24)

10.

Click either Port Type or Port List.
• If you click Port Type, clicking either E_Ports, F_Ports, or FL_Ports will cause this alert to

generate for all ports configured as E_Ports, F_Ports, or FL_Ports respectively.

• If you click Port List, you can choose individual ports by clicking the check box next to each

port number or you can click Set All Ports. Clicking Set All Ports places a check mark

next to each port number. Clicking Clear All Ports will clear the check marks next to each

port number.