Figure 41 address configuration library dialog box, 41 address configuration library dialog box – HP StorageWorks 2.32 Edge Switch User Manual
Page 117
Edge Switch Element Manager user guide 117
7.
In the Configure Addresses - “Active” dialog box, click Activate to activate the configuration or
click Cancel to close without activating.
NOTE:
If you click Cancel after saving, your configuration will still be added to the library
without being activated.
Managing stored address configurations (FICON Management Style)
After address configurations have been created through the Configure Addresses - “Active” dialog
box, they are saved to the Address Configuration Library. Use this procedure to manage address
configurations in the Address Configuration Library.
To manage saved library entries:
1.
Select Configure > Addresses > Stored.
The Address Configuration Library dialog box is displayed.
Figure 41
Address Configuration Library dialog box
2.
Choose a configuration entry by clicking on the row. Then use one of the following procedures.
• To modify a stored configuration:
Click Modify. The Configure Addresses dialog box for the configuration is displayed. For
details on using this dialog box, see ”
Configuring port addresses (FICON management
• To delete a stored configuration:
Click Delete. A warning is displayed before deletion.
• To copy a stored configuration:
Click Copy to copy the configuration and rename/describe it.
When the Copy Address Configuration dialog box is displayed, provide a name and
description for the configuration. Names must be between 1 and 8 characters in length.
Valid characters are uppercase A–Z, 0–9, hyphen (-), and underscore (_). The name may not
be CON, AUX, COMn (n=1–9), LPTn (n=1–9), NUL, or PRN. Descriptions must be between
0 and 24 characters in length. Up to 24 alphanumeric characters are allowed, including
spaces, hyphens and underscores. Click OK and the configuration is added to the library.
• Activate a stored configuration
Click Activate to activate the configuration and send it to the switch for immediate use. A
warning is displayed before the action occurs.