Information and error messages

216

Periodic Date/Time

synchronization must

be cleared.

Action cannot be performed

because the Periodic Date/Time

Synchronization option is active.

Click Periodic Date/Time

Synchronization check box in

Configure Date and Time dialog box

(Configure menu) to clear check mark

and disable periodic date/time

synchronization.

Port binding was

removed from attached

devices that are also

participating in

Switch Binding.

Informational message. You

removed Port Binding from

attached devices, but one or more

of these devices is still controlled

by Fabric Binding.

Review the Switch Binding

Membership List to determine if the

devices should be members.

Port cannot swap to

itself.

Port addresses entered in the

Swap Ports dialog box are the

same.

Ensure that address in the first and

second Port Address fields are

different.

Port diagnostics

cannot be performed on

an inactive port.

Port diagnostics is run on a port in

an inactive state.

Run the diagnostics on an active port.

Port speeds cannot be

configured at a higher

rate than the director

speed.

You configured a port to 2

Gb/sec, and the director speed is

set to 1 Gb/sec.

Set the director speed to 2 Gb/sec in

the Configure Switch Parameter

dialog box.

Port numbers must be

in the range of 0 to

xxx.

When configuring Preferred Paths,

source ports and exit ports must

be in the range of ports for the

switch being configured.

In the Configure Preferred Paths dialog

box, change the numbers in the

Source Port and Exit Port fields to fall

within the port count of the switch on

which you are configuring paths.

Preferred Paths can

not be enabled until

the Domain ID is set

to Insistent. Disable

Preferred Paths, then

configure Switch

Parameters.

If the switch’s domain ID has not

been set to Insistent, the user is not

allowed to activate the Preferred

Path configuration with the Enable

Preferred Paths check box selected.

Close the Configure Preferred Paths

dialog box and click Configure >

Operating Parameters > Switch

Parameters. In the Configure Switch

Parameters dialog box, click the

Insistent check box.

R_A_TOV must be

greater than E_D_TOV.

R_A_TOV must be greater than

E_D_TOV.

Change one of the values so that

R_A_TOV is greater than E_D_TOV

Resource is

unavailable.

The specified operation cannot be

performed because the product is

unavailable.

Verify that the Ethernet connection

between the HAFM appliance and the

director is up or available.