HP StorageWorks 2.32 Edge Switch User Manual
Page 216
Information and error messages
216
Periodic Date/Time
synchronization must
be cleared.
Action cannot be performed
because the Periodic Date/Time
Synchronization option is active.
Click Periodic Date/Time
Synchronization check box in
Configure Date and Time dialog box
(Configure menu) to clear check mark
and disable periodic date/time
synchronization.
Port binding was
removed from attached
devices that are also
participating in
Switch Binding.
Informational message. You
removed Port Binding from
attached devices, but one or more
of these devices is still controlled
by Fabric Binding.
Review the Switch Binding
Membership List to determine if the
devices should be members.
Port cannot swap to
itself.
Port addresses entered in the
Swap Ports dialog box are the
same.
Ensure that address in the first and
second Port Address fields are
different.
Port diagnostics
cannot be performed on
an inactive port.
Port diagnostics is run on a port in
an inactive state.
Run the diagnostics on an active port.
Port speeds cannot be
configured at a higher
rate than the director
speed.
You configured a port to 2
Gb/sec, and the director speed is
set to 1 Gb/sec.
Set the director speed to 2 Gb/sec in
the Configure Switch Parameter
dialog box.
Port numbers must be
in the range of 0 to
xxx.
When configuring Preferred Paths,
source ports and exit ports must
be in the range of ports for the
switch being configured.
In the Configure Preferred Paths dialog
box, change the numbers in the
Source Port and Exit Port fields to fall
within the port count of the switch on
which you are configuring paths.
Preferred Paths can
not be enabled until
the Domain ID is set
to Insistent. Disable
Preferred Paths, then
configure Switch
Parameters.
If the switch’s domain ID has not
been set to Insistent, the user is not
allowed to activate the Preferred
Path configuration with the Enable
Preferred Paths check box selected.
Close the Configure Preferred Paths
dialog box and click Configure >
Operating Parameters > Switch
Parameters. In the Configure Switch
Parameters dialog box, click the
Insistent check box.
R_A_TOV must be
greater than E_D_TOV.
R_A_TOV must be greater than
E_D_TOV.
Change one of the values so that
R_A_TOV is greater than E_D_TOV
Resource is
unavailable.
The specified operation cannot be
performed because the product is
unavailable.
Verify that the Ethernet connection
between the HAFM appliance and the
director is up or available.
Table 10
Element Manager messages (continued)
Message
Description
Action