HP StorageWorks 2.32 Edge Switch User Manual
Page 217
Edge Switch Element Manager user guide 217
Resource is
unavailable.
The specified operation cannot be
performed because the product is
unavailable.
Verify that the HAFM
appliance-to-product link is up. If the
link is up, the HAFM appliance may
be busy. Try the operation again later.
SANtegrity Feature not
installed. Please
contact your sales
representative.
You selected Switch Binding from
the Configure menu, but the
optional SANtegrity Binding
feature is not installed.
Install the SANtegrity Binding key
through the Configure Feature Key
dialog box before using Switch
Binding features.
Send firmware failed.
A firmware download operation
failed.
Retry the firmware download
operation. If the problem persists,
contact the next level of support.
SNMP trap address not
defined.
If an SNMP community name is
defined, a corresponding SNMP
trap recipient address must also be
defined.
Enter a corresponding SNMP trap
recipient address.
Stop diagnostics
failed. The test is
already running.
Diagnostics for the port was not
running and Stop was selected on
the Port Diagnostics dialog box.
Diagnostics for the port quit for
some reason, but the Stop button
remains enabled.
Verify port operation. Retry diagnostics
for the port and select Stop from the
dialog box. If problem persists, contact
the next level of support.
Stop diagnostics
failed. The test was
not running.
This action failed because the test
was not running.
Informational message only—no
action is required
Switch Binding was
removed from attached
devices that are also
participating in Port
Binding. Please review
the Port Binding
Configuration.
The device WWNs were removed
from the director's Switch
Membership List (SANtegrity
Binding feature), but you should
note that one or more of these
devices still has security control in
port binding.
Verify that the security level for each
device is as required by reviewing the
Bound WWN list in the Configure
Ports dialog box.
System diagnostics
cannot run. The
Operational Status is
invalid.
System diagnostics cannot run on
switches with failed ports.
Replace failed ports.
Table 10
Element Manager messages (continued)
Message
Description
Action